MV & LV Switchgear and Ring Main Units (3.6–40.5 kV)

Switchgear is the assembly of switching, protection and control equipment that receives, distributes and safeguards electrical power. This pillar page covers our medium-voltage (3.6–40.5 kV) and low-voltage switchgear, ring main units (RMU) and outdoor circuit breakers — with the type-test evidence behind every rating.

What Is Switchgear?

Switchgear combines circuit breakers, disconnectors, earthing switches, instrument transformers and protection relays inside a grounded, metal-enclosed cubicle. It isolates faults, carries load current and protects downstream equipment. We classify it by voltage class (MV 3.6–40.5 kV, LV ≤ 1 kV), insulation medium (air, SF6, solid) and installation (indoor, outdoor, pad-mounted).

Types of Switchgear

  • Metal-clad MV switchgear — withdrawable circuit-breaker cubicles such as KYN28A (up to 24 kV) and KYN61 (up to 40.5 kV), built to IEC 62271-200.
  • SF6 gas-insulated switchgear (GIS) — sealed, compact cubicles (e.g. RGS 40.5 kV) for space-limited substations.
  • Ring main units (RMU) — compact 12–24 kV units with load-break switches and switch-fuses for distribution rings.
  • Low-voltage switchgear — draw-out assemblies GCK, GCS and MNS for 400 V–690 V distribution.
  • Outdoor / pole-mounted — vacuum circuit breakers (ZW32) and SF6 load-break switches for overhead networks.

Key Ratings and International Standards

Switchgear is specified by: rated voltage (kV), rated normal current (A), rated short-time withstand current (kA, usually 4 s) and peak withstand current (kA), dielectric withstand (power-frequency and lightning-impulse kV), and enclosure protection (IP). The governing standards are IEC 62271-200 and IEC 62271-1, with Chinese equivalents GB/T 3906-2020 and GB/T 11022; LV assemblies follow IEC 61439 / GB/T 7251.

Type Testing and Certification (Evidence)

Our 12 kV ring main units and cable branch boxes are type-tested by Zhejiang Fangyuan Electrical Equipment Testing Co. (CNAS L0116) to GB/T 3906-2020 (equivalent to IEC 62271-200). Representative results:

Model Rated voltage Rated current Short-time withstand Peak withstand Dielectric (PF / LI) IP Standard
GYC-12 12 kV 630 A 20 kA / 4 s 50 kA 42 kV / 75 kV IP4X GB/T 3906-2020
GYF-12 12 kV 125 A (load switch) 31.5 kA / 4 s 80 kA 42 kV / 75 kV IP4X GB/T 11022, DL/T 404
GYV-12 12 kV 630 A 20 kA / 4 s 50 kA 42 kV / 75 kV IP4X GB/T 3906-2020
BYW-12 (cable branch box) 12 kV — arc-class 8FLR / 0.5 s — 42 kV / 75 kV IP44 GB/T 3906-2020

These type tests confirm the insulation coordination, short-circuit strength and enclosure safety of the full-insulated, full-enclosed RMU family for urban and industrial distribution.

Medium-Voltage Switchgear Products

Low-Voltage Switchgear

Outdoor and Pole-Mounted Equipment

Ring Main Units (RMU)

How to Select Switchgear (6 Steps)

  1. Define system voltage and the available short-circuit level at the point of connection.
  2. Choose the insulation type (air / SF6 / solid) by available space and environment.
  3. Size rated current and short-time withstand current (kA and seconds).
  4. Pick indoor, outdoor or pad-mounted by site and accessibility.
  5. Confirm the protection scheme — relay, fused or circuit-breaker.
  6. Verify certifications: type test report, IEC/GB compliance and ISO 9001.

Applications

MV switchgear serves utilities, renewable (solar/wind) substations, industrial plants, data centers, railways and commercial buildings. RMUs and cable branch boxes are the backbone of 12–24 kV urban distribution rings; outdoor vacuum breakers protect overhead lines and transformers.

Related Products and Guides

Frequently Asked Questions

What is switchgear?

Switchgear is the complete assembly of switching, control, protection and metering devices used to receive, distribute and safeguard electrical power. It includes circuit breakers, disconnectors, earthing switches, bushings and relays, housed in a metal-enclosed, grounded cubicle. We supply medium-voltage (3.6–40.5 kV) and low-voltage switchgear for utilities, industry and renewables.

What is the difference between air-insulated and SF6 gas-insulated switchgear?

Air-insulated switchgear (AIS) uses air as the insulation medium and needs larger clearances; it is easy to maintain and lowest cost. SF6 gas-insulated switchgear (GIS) encloses the conductors in SF6, giving a very compact, sealed, maintenance-light cubicle ideal for space-limited or harsh sites. Ring main units (RMU) are often SF6 or solid-insulated for 12–24 kV distribution.

Which standards apply to MV switchgear?

Primary standards are IEC 62271-200 (AC metal-enclosed switchgear for rated voltages above 1 kV up to and including 52 kV) and IEC 62271-1 (common clauses), with Chinese equivalents GB/T 3906-2020 and GB/T 11022. Low-voltage assemblies follow IEC 61439 / GB/T 7251. Our 12 kV ring main units are type-tested to GB/T 3906-2020 (IEC 62271-200 equivalent).

What does type testing of switchgear cover?

Type tests verify the design: dielectric withstand (power-frequency and lightning impulse), thermal and dynamic short-circuit strength, temperature-rise, mechanical endurance, and — for enclosed equipment — internal-arc (arc-fault) classification. Our GYC-12, GYF-12, GYV-12 ring main units and BYW-12 cable branch box are type-tested by Zhejiang Fangyuan, confirming 12 kV rating, 42 kV power-frequency / 75 kV lightning impulse withstand, and IP4X enclosure protection.

How do I select the right switchgear?

Six steps: (1) define system voltage and short-circuit level; (2) choose insulation type (air / SF6 / solid) by space and environment; (3) size rated current and short-time withstand (kA, s); (4) pick indoor, outdoor or pad-mounted by site; (5) confirm protection scheme (relay / fused / circuit breaker); (6) verify certifications (type test report, IEC/GB, ISO 9001). We match any model to your single-line diagram.

What does IP rating mean for switchgear?

IP (Ingress Protection) states how well the enclosure blocks solids and water. MV metal-enclosed switchgear is typically IP4X (finger-safe, no intrusion of objects >1 mm). Outdoor or pad-mounted units and cable branch boxes reach IP44 or higher for rain protection. Higher IP also supports safe operation in dusty or coastal environments.

What is a ring main unit (RMU)?

An RMU is a compact MV switchboard — usually 12–24 kV — that connects a ring or radial distribution network with two incoming feeds and several outgoing feeder circuits, using load-break switches and switch-fuses. It gives fast, visible isolation and fault limitation for urban and industrial networks. Our GYC-12 / GYF-12 / GYV-12 families are full-insulated, full-enclosed RMUs.

How long does MV switchgear last and what maintenance is needed?

Properly specified metal-enclosed switchgear is designed for 20–30 years. SF6 GIS needs almost no maintenance; AIS needs periodic inspection of contacts, mechanisms and insulation. A typical plan is visual and thermal inspection every 1–3 years, plus breaker maintenance per the manufacturer’s operating-count schedule. Internal-arc-tested designs improve personnel safety during faults.