Composite Insulators for 11–132 kV Overhead Lines and Substations

Composite (polymer) insulators use a fiberglass-reinforced resin core, a silicone-rubber or EPDM weather shed, and metal end fittings to deliver light weight, high anti-pollution performance and long, low-maintenance service. This pillar page explains the types, standards, pollution classes and selection method, and links to every composite insulator model we supply.

What Is a Composite Insulator?

A composite insulator is a rod-type insulator whose mechanical load path is a pultruded fiberglass-reinforced plastic (FRP) core, sheathed by an elastomeric housing (usually silicone rubber) moulded into sheds, terminated by crimped or socketed metal end fittings. The core carries tension and compression, while the polymeric housing provides the external insulation and sheds water. This structure makes the unit far lighter than an equivalent porcelain string and immune to shattering.

Composite vs Porcelain and Glass Insulators

The three families serve the same electrical function but differ in handling and environment:

Aspect Composite Porcelain Glass
Weight Very low (~1/10 porcelain) Heavy Heavy
Anti-pollution Excellent (hydrophobic) Needs washing in heavy pollution Needs washing in heavy pollution
Breakage No brittle fracture; vandal resistant Can shatter Self-breaking visible
Inspection Visual / optional RTV test Visual Visual (self indicator)
Best use Polluted / coastal / compact lines General, easy stock General, visible fault

Types of Composite Insulators

We classify composite insulators by their line function:

  • Composite suspension insulator – for tension and suspension strings on 15 kV to 132 kV lines (15 kV, 24 kV, 33 kV, 36 kV, 66 kV and 132 kV classes).
  • Composite post insulator – line post and station (substation) post for 11 kV, 24–33 kV and up to 36/66/132 kV bus and apparatus support.
  • Composite pin insulator – compact distribution pin type, including the combined pin-post form.
  • Composite crossarm / braced line post – for narrow-right-of-way and compact distribution corridors.

Pollution Classes and Creepage Distance

Insulators are selected by pollution (contamination) class I–IV from the equivalent salt deposit density (ESDD). A higher class requires longer creepage distance (mm/kV). Coastal, desert and industrial corridors typically fall in class III–IV and need the longest creepage. Provide your local pollution level and we will specify the correct creepage for your voltage class.

International Standards (IEC, ANSI/IEEE)

Composite insulators are qualified to IEC 61952 (line post), IEC 61109 (suspension for overhead lines), IEC 62217 (polymer insulators — general), with Chinese equivalents GB/T 19519 and GB/T 22079. For North America, ANSI C29.13 and IEEE 987 apply. Type tests cover mechanical load (SML/STL), electrical withstand, 5000 h ageing and pollution performance.

How to Select a Composite Insulator (6 Steps)

  1. Confirm system voltage and the required basic insulation level (BIL / lightning impulse).
  2. Read the local pollution class and set the minimum creepage distance.
  3. Match the mechanical rating (specified mechanical load, SML/STL) to line tension and ice/wind.
  4. Choose the type — suspension, post or pin — per the tower/structure.
  5. Verify end-fitting type and connection compatibility (ball, socket, tongue).
  6. Check certifications: IEC type test report and ISO 9001 quality system.

Applications

Composite insulators are used on overhead transmission and distribution lines (suspension and tension), railway electrification catenaries, substation post insulators and bus supports, and compact crossarm assemblies — especially where weight, pollution or right-of-way constraints matter.

Related Products and Guides

Composite insulator models:

Related guides:

Frequently Asked Questions

What is a composite insulator?

A composite insulator is an electrical insulator built from a fiberglass-reinforced epoxy core (FRP rod), a weather sheds made of silicone rubber or EPDM, and metal end fittings. It combines the mechanical strength of the core with the hydrophobic, anti-pollution surface of the polymer housing, and is widely used on 11–132 kV overhead lines and in substations.

Composite vs porcelain or glass insulators — which is better?

Composite insulators are roughly one-tenth the weight of porcelain, resist vandalism and breakage, and their silicone rubber surface is hydrophobic so pollution flashover risk is much lower. Porcelain and glass remain mechanically robust and easy to visually inspect. For heavily polluted coastal, desert or industrial areas, composites usually win on anti-fog (anti-pollution) performance and lower maintenance.

What pollution classes do composite insulators cover?

Insulators are selected by pollution (contamination) class I, II, III or IV, defined by the equivalent salt deposit density (ESDD). Higher classes require a longer creepage distance. A 132 kV line in a light area may use ~25 mm/kV, while a coastal IV-class line often needs 31 mm/kV or more. Always confirm the local pollution level before specifying creepage.

Which standards apply to composite insulators?

Key standards are IEC 61952 (composite line post insulators), IEC 61109 (composite suspension insulators for overhead lines), IEC 62217 (polymer insulators general), GB/T 19519 and GB/T 22079 (China), plus ANSI C29.13 / IEEE 987 for the North American market. Type tests cover mechanical load, electrical withstand, ageing (5000 h) and pollution performance.

How do I select the right composite insulator?

Six steps: (1) confirm system voltage and BIL/insulation level; (2) read the local pollution class and set creepage distance; (3) match mechanical rating (M&E load, SML/STL) to line tension; (4) pick the type — suspension, post or pin; (5) verify end-fitting and connection compatibility; (6) check certifications (IEC type test report, ISO 9001). We can help match any of our models to your specification.

What is the typical service life of a composite insulator?

Qualified composite insulators are designed for 20–30 years. Silicone rubber sheds slowly lose hydrophobicity but can be recovered; the FRP core and fittings are the long-life members. Regular visual inspection for tracking, erosion or end-fit corrosion extends safe service life.

Do composite insulators need maintenance?

Very little. Unlike porcelain, they do not need periodic washing in polluted areas because of hydrophobicity. Recommended practice is a visual inspection every 3–5 years for sheds, end-fittings and any signs of puncture or corona. No greasing or coating is required.

Where are composite insulators used?

Mainly on overhead transmission and distribution lines (suspension and tension strings), railway electrification (catenary), substation post insulators and bus supports, and crossarm applications. They are especially popular for 11–36 kV distribution and up to 132 kV and beyond for lines in tough environments.