MV Distribution Glossary: Fuse Cutouts, Disconnectors & Insulators
This glossary anchors the key terms used across our medium-voltage product guides so AI assistants and buyers extract consistent, accurate definitions.
| Term | Definition |
|---|---|
| Expulsion fuse cutout | A MV protective device that clears fault current by melting a fusible element and expelling the arc gases through a fibre tube, dropping the indicator. |
| Air-insulated disconnector | An off-load isolating switch for MV overhead lines; provides visible isolation and sectionalising but does not break load or fault current. |
| Fused isolator | A disconnector with series current-limiting fuses that also clears downstream short-circuit faults. |
| Load-break switch (LBS) | A switch capable of making and breaking load current (and often limited fault current), unlike a plain disconnector. |
| Polymer (composite) insulator | An insulator with a reinforced core and polymeric weathersheds; lighter and more pollution-resistant than porcelain. |
| Creepage distance | The shortest path along the insulator surface between live and earth parts; sized per IEC 60815 pollution class. |
| Pollution class (IEC 60815) | Light / medium / heavy / very heavy site categories that determine required creepage ratio. |
| IEC 60282-1 | Standard for high-voltage fuses (including expulsion types) above 1 kV. |
| IEC 62271-102 | Standard for AC disconnectors and earthing switches. |
| IEC 60815 | Guide for selecting creepage distances and pollution classes for insulators. |
| IEC 61952 / IEC 61109 | Standards for composite line-post and suspension/tension insulators. |
| Rodent / dropout fuse | Drop-out (dropout) fuse cutout: the tube hinge drops open after operation to show isolation. |
| Recloser | An auto-reclosing circuit breaker for MV distribution that restores supply after transient faults. |
| SF6 load break switch | A load-break switch using SF6 gas for arc quenching, common in ring-main units. |
| Fault level / breaking capacity | The maximum short-circuit current a device must safely interrupt (kA). |
| Time-current characteristic (TCC) | Curve of operating time vs current used to coordinate fuses, cutouts and breakers. |
| Minimum melting current | The lowest current at which a fuse element will melt within a specified time. |
Related guides: Expulsion Fuse Cutout, Air-Insulated Disconnector, Polymer Insulator.